How to...
This is an example how to read a device's basic cluster.
- Press the most right bullet on the node to expand the available clusters (1).
- Make sure you have selested the
Cluster Infopane (3). - Select the cluster of your choice (2) and scroll down to the
readbutton (4) if required and press it.
In case the device is a light sleeper, the attributes should be read after roughly 7 seconds without any further requirement of action (the node blinks blue first and then green). If the device is a deep sleeper (the node blinks red), you need to wake the device first. This is typically done e.g. by a brief press on the device's physical button or by triggering its function (move, open/close). Please take note that the button must be pressed 1-2 seconds afterwards.

This is an example how to to manually bind a server cluster.
- In deconz GUI, select
Panelsand thenBind dropbox.

For your chosen device as well as the coordinator (blue node), press the most right bullet on the node to expand the available clusters.
- For the coordinator: Drag&drop
01 Home Automation Endpointas Destination (1). - For the device: Select the
Simple Meteringcluster (taken here as example) and also drag&drop it as Source (2). Take note that this must be a server cluster (colored blue). - Press
bind(3).
In case the device is a light sleeper, the status of the binding (4) should be returned after roughly 7 seconds without any further requirement of action (the node blinks blue first and then green). If the device is a deep sleeper (the node blinks red), you need to wake the device first. This is typically done e.g. by a brief press on the device's physical button or by triggering its function (move, open/close). Please take note that the button must be pressed 1-2 seconds afterwards.

This is an example how to to manually configure attribute reporting.
For your chosen device, press the most right bullet on the node to expand the available clusters.
- Select the cluster of your choice (
Electrical Measurementcluster taken here as example) (1). - Double click on the value of the attribute of your choice (
0x0505taken here as example) (2). - It is recommended to first read the current reporting configuration of the attribute (press
read config).UNSUPPORTED_ATTRIBUTEas return status indicates the attribute is non-reportable,NOT_FOUNDindicates a reportable attribute which has not yet been configured. - In the opened Attribute Editor, change the values according to your needs (3).
- When done, press
write config(4).

In case the device is a light sleeper, the status of the reporting configuration (5) should be returned after roughly 7 seconds without any further requirement of action (the node blinks blue first and then green). If the device is a deep sleeper (the node blinks red), you need to wake the device first. This is typically done e.g. by a brief press on the device's physical button or by triggering its function (move, open/close). Please take note that the button must be pressed 1-2 seconds afterwards.
Home Remember : Not all devices listed here are supported by deconz.