Original file line number Diff line number Diff line change
Expand Up @@ -929,7 +929,10 @@ func (job *RedisSwitchPreCheck) checkReplicationSync(newMasterConn *myredis.Redi
var masterTime, masterDbsize, slaveTime int64
oldMasterAddr := fmt.Sprintf("%s:%d", storagePair.MasterInfo.IP, storagePair.MasterInfo.Port)
newMasterAddr := fmt.Sprintf("%s:%d", storagePair.SlaveInfo.IP, storagePair.SlaveInfo.Port)

if err := job.trySetHeartBeatWhenDbmonStoped(storagePair); err != nil {
time.Sleep(time.Second * 2)
job.trySetHeartBeatWhenDbmonStoped(storagePair)
}
if err := newMasterConn.SelectDB(1); err != nil {
return fmt.Errorf("[%s] select db 1, exec cmd err:%+v", newMasterAddr, err)
}
Expand Down Expand Up @@ -976,6 +979,30 @@ func (job *RedisSwitchPreCheck) checkReplicationSync(newMasterConn *myredis.Redi
return nil
}

// setHeartBeatWhenDbmonStoped # here we just set on the master heartbeat:
func (job *RedisSwitchPreCheck) trySetHeartBeatWhenDbmonStoped(storagePair InstanceSwitchParam) error {
oldMasterAddr := fmt.Sprintf("%s:%d", storagePair.MasterInfo.IP, storagePair.MasterInfo.Port)
oldMasterConn, err := myredis.NewRedisClientWithTimeout(oldMasterAddr,
job.params.ClusterMeta.StoragePassword, 0, job.params.ClusterMeta.ClusterType, time.Second*10)
if err != nil {
job.runtime.Logger.Warn("[%s] conntect 2 old master failed :%+v", oldMasterAddr, err)
return err
}
defer oldMasterConn.Close()

if err := oldMasterConn.SelectDB(1); err != nil {
job.runtime.Logger.Warn("[%s] select db 1 on master failed :%+v", oldMasterAddr, err)
return err
}
job.runtime.Logger.Info("[%s] try reset dbmon heartbeat key [%s] value 2 current", oldMasterAddr, fmt.Sprintf("%s:time", oldMasterAddr))
rst := oldMasterConn.InstanceClient.Set(context.TODO(), fmt.Sprintf("%s:time", oldMasterAddr), time.Now().Unix(), 0)
if rst.Err() != nil {
job.runtime.Logger.Warn("[%s] set on old master failed :%+v", oldMasterAddr, err)
return err
}
return nil
}

// precheckStorageLogin make sure all todo switch redis can login
func (job *RedisSwitchPreCheck) precheckStorageLogin() error {
wg := &sync.WaitGroup{}
Expand Down
8 changes: 4 additions & 4 deletions dbm-ui/backend/flow/consts.py
Original file line number Diff line number Diff line change
Expand Up @@ -57,10 +57,10 @@
DEFAULT_REDIS_INSTANCE_DATABASES = 2
DEFAULT_REDIS_CLUSTER_DATABASES = 1

# 切换时, 默认允许多久心跳
DEFAULT_MASTER_DIFF_TIME = 61
# 切换时, 允许多少秒丢失
DEFAULT_LAST_IO_SECOND_AGO = 100
# 切换时, 默认允许多久心跳 61->11 @20251121
DEFAULT_MASTER_DIFF_TIME = 11
# 切换时, 允许多少秒丢失 100->30 @20251121
DEFAULT_LAST_IO_SECOND_AGO = 30

# 默认Riak端口
DEFAULT_RIAK_PORT = 8087
Expand Down