Releases: git-moss/DrivenByMoss
Releases · git-moss/DrivenByMoss
26.4.0 (Bitwig 5.3+)
- Maschine JAM
- New: Using Shift in combination with the faders allows for smaller changes. Furthermore, the value does not jump when the fader is touched.
- New: Added setting Slow Fader Change to be able to store the small fader changes. Toggle with Shift+Select.
- New: Added setting Startup mode to select the mode which will be activated on startup.
- Fixed: Shift mode does not activate if Shift button was used in combination with another button.
- MCU
- New: Startup mode: Select the mode which will be activated on startup.
26.3.0 (Bitwig 5.3+)
- Maschine
- New: Shift+ARRANGE(R)/IDEAS activates Edit layout.
- Maschine Mk2/Studio
- New: CHORDS mode can now be accessed as well. To support it the behaviour of the PAD MODE button has been changed. Press it multiple times to toggle between PAD MODE, KEYBOARD and CHORDS mode. Use Shift+PAD MODE to access the settings of the respective mode.
- MCU
- New: Added new setting Encoder Knob Slow Down which allows to slow down the main encoder.
- New: Renamed option Off to None for the settings 'Main display', 'Has a second display', 'VU Meters' and 'Display Colors'.
- Fixed: VU meters can be toggled on/off with Global View again.
26.2.1 (Bitwig 5.3+)
- Electra One
- Fixed: The first page (mixer) was not selected on startup, which means that if a different one was selected it did not work.
- Fixed: The 'Behaviour on Pause' setting was completely ignored.
- Native Instruments Kontrol Mk3
- Fixed: Names in different mix modes are reduced to 1 line to fix overflow of the graphics.
26.2.0 (Bitwig 5.3+)
- Native Instruments Kontrol Mk3
- New: In device mode up/down changes tracks.
- Fixed: First track of the current page could not be muted/soloed.
- Fixed: Selecting devices did not fully work after removing/adding a device.
- Fixed: Fixed several issues caused by the presence of a NKS device (Kontrol, Kontakt 7/8). Note: Since the special NKS mode is not notified, device and track modes cannot be changed when a NKS device is selected!
- Push 2
- New: Added a graphical visualisation for the pad sensitivity curve.
- Push 3
- New: MPE Pitchbend does now work with the selected scale!
- New: Added support for configuring the pad sensitivity curve incl. a graphical visualisation.
26.1.0 (Bitwig 5.3+)
- Removed support for Melbourne Instrument Roto-Control. Use the native Bitwig implementation instead.
26.0.0 (Bitwig 5.3+)
- New: Added 'stop is queued' state to the session grid clips. Signal is the same as queued playing.
- Faderfox EC4
- Fixed: Updated template to make it work with current Faderfox web-interface.
- Generic Flexi
- Fixed: Parameter #1 reset on 1st instrument did not work.
- MCU
- Fixed: Improved formatting of bars to align with the text on the hardware.
- Native Instruments Kontrol Mk2
- New: Loop+Encoder changes Loop start
- New: The browser presets can be navigated by turning the encoder and confirmed by pressing the encoder.
- Native Instruments Kontrol Mk3
- New: Added support for NHIA protocol v4:
- Support for the Shift-Button
- Slow change of values when using knobs in combination with Shift
- Zoom in/out with Shift+Encoder
- Shift+Quantize: switches the options for recording quantize
- Shift+Auto: toggle clip automation recording
- Support for native Plug-in mode
- Support for changing tempo
- Colored track VUs
- Added detection of Maschine 3 plugin
- Loop/Shift+Loop+Encoder changes Loop start/length
- Mixer modes are now switched by pressing DAW multiple times
- Added a new layer mode
- The browser can be used (see the manual for details)
- Support for the Shift-Button
- New: Added support for NHIA protocol v4:
- Push 2/3
- New: Improved state icons in clip mode.
- New: Having pressed the Mute/Solo for a longer time does deactivate toggling Mute/Solo on button release.
- New: Improved lookup on latest macOS.
- XJam
- New: The knobs are now real relative knobs! Requires Firmware 1.55 and update the template incl. in DrivenByMoss.
25.5.0 (Bitwig 5.3+)
- New: Added support for Intuitive Instruments Exquis
25.1.1 (Bitwig 5.3+)
- Akai APC40 / APC40mkII
- New: Shift mode is automatically closed again if Shift was used in combination with a button.
- Electra One
- New: The 3rd knob on the bottom row of the transport page controls now the hovered parameter introduced in Bitwig 5.3. It is required to reinstall the template.
- Fire
- Fixed: Switching Project and Track parameter pages did jump by 8 and not 1.
- Maschine
- New: The 4D-Encoder can now control the hovered parameter introduced in Bitwig 5.3. Press it to toggle to that function.
- MCU
- New: The hovered parameter introduced in Bitwig 5.3 can now also be controlled with the master fader.
25.1.0 (Bitwig 5.3+)
- Fire
- New: Press Alt+SELECT knob to toggle thes window of the current device (was only SELECT).
- New: Press Shift+Alt+SELECT knob to toggle the on/off state of the current device (was Alt+SELECT).
- New: Press SELECT to toggle controlling the hovered parameter introduced in Bitwig 5.3.
- Generic Flexi
- New: Added new function 'Device: Last Parameter' which controls the hovered parameter introduced in Bitwig 5.3..
- MCU
- New: The encoder can now control the hovered parameter introduced in Bitwig 5.3. To toggle the feature assign the Last hovered/clicked parameter to a function key or a footswitch.
- OSC
- New: Added new commands and values for /device/lastparam/.
- Push 1-3
- New: The Last Touched setting of the ribbon controls now the hovered parameter introduced in Bitwig 5.3.
25.0.2 (Bitwig 5.2+)
- Requires Bitwig 5.3+
- Implemented adaptive scrolling for play position as well as the loop start and length on all devices which provide these functions.
- ROTO CONTROL
- New: Support for stepped parameters. Since Bitwig cannot provide the option names, they are labelled Option 1 - Option N.
- Fixed: Track button states could get inconsisten when tracks were added or removed.
- Fixed: Parameter mapping did only work for parameters on the first page (did crash for all others). Regression in 25.0.1.